Infrared Inoculation Loop Sterilizer

Infrared Inoculation Loop Sterilizer
Details:
Model: QW-MJ-15
Central Zone High Temperature: 850 ± 25℃
Disinfection Product Outer Diameter: Ф15mm
Heating Zone Total Length: 165mm
Send Inquiry
Description
Send Inquiry

Hangzhou Qiwei Instrument Co., Ltd. is one of the leading manufacturers and suppliers of infrared inoculation loop sterilizer in China. With a professional production team, we are able to meet the needs of the majority of our customers. Welcome to wholesale bulk infrared inoculation loop sterilizer in stock here from our factory. We also accept customized orders.

 

 
 

 

The Qiwei Infrared Inoculation Loop Sterilizer is intended for regular sterilization of suitable inoculating needles, inoculating loops, and another small laboratory equipment. It is an effective substitute for flame-based sterilization methods for appropriate biology workflows because it uses a ceramic infrared heat factor to create a high-temperature heating zone without an open flame.

To support various tool sizes, the product line includes versions with 15 mm and 35 mm openings. According to the specifications, the main heating zone registers 850 25 degrees Celsius. The lightweight design makes for a useful option for routine tool sterilization where an open flame is not preferred for laboratories, research institutes, educational facilities, and distributors of laboratory equipment.

 

product key technologies
3
01.

Introduction

The infrared inoculation loop sterilizer adopts an intelligent temperature controller, and the sterilization temperature is set according to the experimental requirements. There is no open fire operation. The heating component adopts a high-efficiency ceramic infrared heating pipe, which has the advantages of small size, light weight, simple operation, fast temperature rise, high temperature, and long service life. It can quickly sterilize small instruments, not affected by external factors, improve the working efficiency of the experiment, and can adapt to various experimental environments. It is a good assistant for experimental operators at all levels of health and epidemic prevention stations, environmental monitoring stations, food health supervision and inspection institutes, hospitals, biological products institutes, drug inspection institutes, food factories, daily chemical plants, colleges and universities, and scientific research units.

02.

Principle

The infrared inoculation ring sterilizer uses infrared rays to work, and 'bombards' bacteria and viruses through high-energy particles radiated by infrared rays to inactivate them. At the same time, infrared rays can also stimulate water molecules to form active water and further enhance the disinfection effect. This sterilizer has a broad spectrum, can kill including bacteria, viruses, fungi, parasites and other microorganisms, so as to achieve the purpose of complete disinfection and sterilization.

1

How Infrared Heating Works in an Inoculation Loop Sterilizer?

 

An infrared immunisation circle sterilizer uses an electrically heated ceramic infrared element to create a high-temperature area inside a thin heating chamber. Appropriate inoculating loops and needles are inserted into the designated heat area according to the company's instructions. The high temperatures provides thermal care of the device area and helps remove bacterial contamination when the specified operating procedure is followed.

Unlike an alcohol lamp or Bunsen stove, the device does not depend on an uncovered fire during normal operation. This can be helpful in laboratory processes where open embers are restricted or not preferred. The small heating chamber even provides a defined area for treating suitable little tools, helping users have out repeated sterilization steps without maintaining a constantly burning flame.

The product's listed key heating-zone temperature is 850± 25°C. Qiwei describes the sterilization process for suitable tools as quick, with a mentioned operation time of about 5–7 seconds. The real cycle should follow the official guidelines for the device type, insertion method, and operating conditions.

A flame-free style does not mean that the equipment is great, risk-free, or appropriate for every lab environment. The heating chamber and inserted resources can reach high temperature. Customers must avoid touching warm components, prevent call with flammable materials, and allow instruments to great where required by the laboratory process.

 

Feature

 

1. Inoculating loop sterilization is safe and hassle-free, fully compatible as an alcohol lamp replacement.

2. The internal heating zone temperature goes beyond 800℃, with fast sterilization completed in 5–7 seconds.

3. Portable compact structure, simple to operate; elegant appearance, convenient cleaning and excellent durability.

4. Supports application scenarios inside anaerobic laboratories.

5. Organic residues are incinerated deep inside the ceramic funnel, effectively preventing infectious splashing and mutual cross-contamination.

6. Special intelligent control logic optimizes heating operation, prolongs core heating component life and enhances use reliability and safety.

 

Technical Parameter

Model

QW-MJ-15

QW-MJ-15S

QW-MJ-35

QW-MJ-35S

Central Zone High Temperature

850 ± 25℃

Disinfection Product Outer Diameter

Ф15mm

Ф35mm

Heating Zone Total Length

165mm

120mm

Heating Time

15min

Environmental Temperature

5-40℃

Fuse

3A

Power Supply

220V 50Hz

Power

150W

250W

Weight

1.3kg

1.6kg

Size

170×105×180mm

170×105×200mm

Timing Function

No

0 - 999 minutes

No

0 - 999 minutes

Application

 

1. Inoculating Loop Sterilization

The infrared immunisation circle sterilizer is designed for suitable inoculating loops used in microbiology procedures. Its high-temperature heat area supports repeated thermal treatment between suitable laboratory operations. Users should adopt the approved laboratory process and the company's instructions for insertion, exposure time, and cooling before contacting the second sample.

2. Inoculating Needle and Small Tool Treatment

Suitable inoculating needles and other appropriate little metal tools may be treated using the designated heat chamber. Before use, check the device dimensions against the starting size and efficient heat area of the selected model. 

3. Microbiology and Culture Laboratories

Research institutes, college laboratories, medical microbiology facilities, and food-testing laboratories may use an ultraviolet inoculation loop sterilizer as part of their habit tool-handling workflow. Its flame-free activity can be helpful in contexts where open flames are not preferred, subject to local safety procedures and the laboratory's risk assessment.

4. Apply in a Biological Safety Cabinet

An infrared immunisation circle sterilizer may be considered for use in a natural health case only when the cabinet maker permits the system and the laboratory's biosafety assessment and standard operating procedures approve the setup. The equipment must not obstruct flow, interfere with cupboard efficiency, or introduce undesirable heat or ignition risks. A flame-free heater may not automatically become assumed to get approved for every cupboard or every biosafety application.

5. Foods, Environmental, and Educational Laboratories

The gadget may help regular microbiological work in food inspection, climate monitoring, teaching, and research laboratories where appropriate inoculating tools require repeated thermo treatment. Users should choose the design according to tool dimensions and observe the laboratory's approved decontamination and handling procedures.

 

Safety Features and Operating Precautions

 

The infrared inoculation circle sterilizer operates at a higher temperatures and should be handled as a heat-generating lab device. Place it on a secure, heat-resistant work area and keep combustible materials away from the heat area. Do not contact the heat chamber or just heated tools with bare hands.

Before functioning, check that the system is correctly connected to the specified energy supply and that the selected starting is suitable for the tool being treated. Place tools according to the consumer manual, and prevent forcing large items into the chamber. Let heated tools to great in accordance with the laboratory process before handling samples.

When using the autoclave in a natural safety cupboard, confirm that the layout is permitted by the cabinet maker and the laboratory's biosafety procedures. Do not block airflow cutouts or place the device where it interferes with healthy acting methods. If strange odor, obvious damage, or unusual operation occurs, change off the device and arrange an inspection before reuse.

 

Hot Tags: infrared inoculation loop sterilizer, China infrared inoculation loop sterilizer manufacturers, suppliers, factory, Infrared Inoculation Loop Sterilizer, Lab Steam Autoclave, sterilizer

Send Inquiry
Send Inquiry