Portable Conductivity Tester

Portable Conductivity Tester
Details:
Model: DDB-11A
Measuring Range: (0 ~ 199.9) μs/cm; (200 ~1999)μs/cm; (2.00 ~ 19.99)ms/cm; (20.0 ~ 199.9)ms/cm
Resolution: 0.1/1μs/cm; 0.01/0.1 ms/cm
Accuracy: Electro-meter: ±1.0% FS; Matching: ±1.5% FS
Send Inquiry
Description
Send Inquiry

Hangzhou Qiwei Instrument Co., Ltd. is one of the leading manufacturers and suppliers of portable conductivity tester in China. With a professional production team, we are able to meet the needs of the majority of our customers. Welcome to wholesale bulk portable conductivity tester in stock here from our factory. We also accept customized orders.

 

 
 
product key technologies
Portable Conductivity Tester2

Lightweight and pocket-friendly, this portable conductivity tester can be taken anywhere conveniently. It takes readings in a flash, works wirelessly and runs for a long time on a single charge, with straightforward handling procedures.

As a physical parameter, electrical conductivity is a physical quantity that measures a substance's ability to conduct electricity, reflecting the capacity of ions in a solution to carry electric current. When freely moving ions are present in a solution, they undergo directional migration under the influence of an electric field, thereby forming an electric current. The conductivity of water is correlated with the amount of inorganic acids, bases, and salts it contains. When their concentrations are low, conductivity increases with concentration. Therefore, this parameter is often used to infer the total ion concentration or salinity of water.

To test solutions of high or low conductive performance, choose electrodes with varied cell constants. Configure the system according to the mounted electrode, and the unit will automatically compute and present the final measured data.

To obtain reliable data, there are a few points to keep in mind when using the instrument:

 

Regular calibration: Calibrate the instrument with standard solutions - just like using standard weights to calibrate a scale - to ensure the accuracy of your measurement results.

Proper cleaning: Before and after each measurement, be sure to gently rinse the electrode with pure water and blot it dry with soft tissue paper, to avoid contaminating the sample or damaging the electrode.

Understanding the reading: The conductivity value itself is an aggregate indicator. It tells you the total amount of conductive substances in the water, but it cannot distinguish which specific ions are present. An unusually high reading typically suggests possible water contamination or high salinity.

 

Working condition

 

Ambient Temperature

0 ~ 40 ℃ Relative humidity: < 85%

Power Supply

4×AAA batteries

Vibration

No significant vibration

Interference

There is no other strong magnetic field interference except the geomagnetic field

Optional Electrode Specification Constants

0.1, 1, 10

Size

180×80×30 mm

Weight

0.8KG

 

Technical parameters

 

Model

DDB-11A

Measuring Range

(0 ~ 199.9) μs/cm; (200 ~1999)μs/cm; (2.00 ~ 19.99)ms/cm; (20.0 ~ 199.9)ms/cm

Resolution

0.1/1μs/cm; 0.01/0.1 ms/cm

Accuracy

Electro-meter: ±1.0% FS; Matching: ±1.5% FS

Temperature Compensation

10-50 °C manual compensation

Temperature Coefficient

2.0%/°C

Basic Configuration

1. DJS-1E (platinum black) electrode
2. 1408μs/cm conductivity standard calibration mount
3. 4×AAA batteries

 

Hot Tags: portable conductivity tester, China portable conductivity tester manufacturers, suppliers, factory