Hangzhou Qiwei Instrument Co., Ltd. is one of the leading manufacturers and suppliers of benchtop multi-parameter cadmium ion concentration meter in China. With a professional production team, we are able to meet the needs of the majority of our customers. Welcome to wholesale bulk benchtop multi-parameter cadmium ion concentration meter in stock here from our factory. We also accept customized orders.
Benchtop Cadmium Ion Analyzer for Wastewater and Water Quality Testing
Cadmium ion concentration in aqueous samples can be measured in a lab setting with the PXS-Cd Benchtop Cadmium Ion Analyzer.
For controlled laboratory analysis, it offers measuring functions for pCd, cadmium ion concentration, and mV. When paired with the proper cadmium ion detecting system, the device may directly show cadmium concentration and allow temperature correction.
Environmental water analysis, wastewater inspection, laboratory research, industrial water testing, and other applications where cadmium content needs to be assessed as part of a more comprehensive water-quality assessment are examples of typical applications.
product key technologies

The PXS-Cd Benchtop Multi-Parameter Cadmium Ion Concentration Meter serves chiefly to measure the level of cadmium ions present in water-based liquids. This device incorporates purpose-driven structural and functional designs, rendering it particularly appropriate for high-purity water networks within power stations. In such settings, it allows exact tracking of water quality indicators including steam, recirculating water, and boiler makeup water. Moreover, this instrument finds broad utility across contexts such as academic labs, research organizations, petrochemical operations, and microelectronics fabrication. It facilitates determination of cadmium ion concentration in natural water sources, industrial effluent, and diverse aquatic habitats.
Cadmium Detection Limit
The entire analytical system, including the cadmium ion-selective electrode, calibration standards, sample matrix, conditioning solution, temperature, and measurement technique, should be used to assess the performance of cadmium measurements.
A Cd²⁺ measurement range of 0.19 g/L to 19 g/L, a pCd range of 0.00–6.00, and a pCd resolution of 0.01 are listed in the current PXS-Cd specification.
Instead of drawing conclusions from the instrument's pCd resolution, the actual technique detection limit for low-level wastewater or environmental monitoring should be determined and confirmed under the specified sample matrix.
In order to validate the proper electrode, calibration standards, and analytical process, users who need ppm- or ppb-level cadmium analysis should supply the expected concentration range and sample matrix prior to ordering.
Technical parameters
|
Model |
PXS-Cd |
|
Measuring Range |
pCd: (0.00~6.00)pCd; Cd2+: 0.19g/L~19g/L; mV: (-1800~1800)mV |
|
Resolution |
0.01 pCd |
|
Basic Error of the Electronic Unit |
±0.02 pCd ±1 word |
|
Calculation Error |
±0.3% |
|
Repeatability Error |
≤±0.03 pCd ±1 word |
|
Stability of the Electronic Unit |
±0.02pCd/3h |
|
Temperature Compensation Range |
(5.0~ 50.0)℃ |
|
Size |
210×190×80mm |
|
Weight |
1.5KG |
Working condition
|
Ambient Temperature |
(5~40)℃ |
|
Relative Humidity |
≤80% |
|
Power Supply |
AC 220V ± 22V; Frequency 50 ± 1Hz |
|
Interference |
There is no interference from other magnetic fields except the Earth's magnetic field |
|
Vibration |
No significant vibration |
Features
- The PXS-Cd benchtop multi-parameter cadmium ion concentration meter adopts single-chip microcomputer technology. It features simple and convenient operation with intuitive and accurate digital display.
- It is equipped with manual and automatic temperature compensation functions. When the temperature electrode is connected, the instrument enables automatic temperature compensation and displays the current temperature. When the temperature electrode is disconnected, the instrument switches to manual temperature compensation and shows the manually set temperature value. The temperature electrode is an optional accessory. Customers who require it shall specify it when placing an order.
- In addition to pCd value display, the instrument also supports the display of cadmium ion concentration [Cd] value.
Calibration Standards
Whenever feasible, calibration standards should fall within the samples' anticipated cadmium concentrations.
Step 1: Choose Standards
Select cadmium standards that fall within the desired measurement range.
Step 2: Get the Standards Ready
Utilizing the suggested concentration levels and scientific techniques, prepare standards.
Step 3: Use Conditioning
When necessary, consistently add the designated ISA or conditioning solution.
Step 4: Adjust the Concentration from Low to High
Allow the electrode response to stabilize at each stage as you measure the calibration standards in the suggested order.
Step 5: Check the Calibration
Prior to sampling unidentified wastewater samples, examine the calibration response.
Step 6: Measure the Samples
Use the same measurement and conditioning process that was used for calibration.
The established analytical technique should be followed when choosing calibration standards, blanks, replicate measurements, and quality-control samples for trace-level applications.
fAQ
1.What is measured by a cadmium ion analyzer?
A cadmium ion analyzer uses an appropriate cadmium sensing device to measure the concentration of cadmium ions, or pCd, in an aqueous sample.
2.Is it able to detect cadmium in wastewater?
Cadmium ions in water-based samples, such as industrial effluent and environmental water, can be measured in a lab using the PXS-Cd.
3.Is it possible to quantify ppb-level cadmium with the PXS-Cd?
For the entire measuring apparatus and sample matrix, the necessary detection limit needs to be confirmed. A ppb claim should not be made without supporting validation data because the present published PXS-Cd specification does not include a ppb-level MDL.
4.What is pCd?
In ion-selective electrochemical measurement, pCd is a logarithmic representation of cadmium ion activity/concentration.
5.Why is an ISA solution employed?
When the electrode's analytical process calls for it, an Ionic Strength Adjuster can assist in creating more uniform ionic conditions between standards and samples.
6.Does the device follow EPA guidelines?
Analytical processes are specified by EPA methodologies, and compliance is contingent upon the full validated method. The PXS-Cd is not necessarily EPA-certified or compliant just because it has an EPA cadmium technique.
Hot Tags: benchtop multi-parameter cadmium ion concentration meter, China benchtop multi-parameter cadmium ion concentration meter manufacturers, suppliers, factory, Benchtop Multi Parameter Nitrate Ion Concentration Meter, electrochemical instruments, Portable Multi Parameter Calcium Ion Concentration Meter, Portable Multi Parameter Iodide Ion Concentration Meter, Portable Multi Parameter Kalium Ion Concentration Meter, Portable Multi Parameter Sodium Ion Concentration Meter
