Handheld Turbidity Meter

Handheld Turbidity Meter
Details:
Model: ZD-2A, ZD-10A
Principle: 90° scattered light
Minimum Indication: 0.1 NTU
Measuring Range: 0~200 NTU, 0~1000 NTU
Send Inquiry
Description
Send Inquiry

Hangzhou Qiwei Instrument Co., Ltd. is one of the leading manufacturers and suppliers of handheld turbidity meter in China. With a professional production team, we are able to meet the needs of the majority of our customers. Welcome to wholesale bulk handheld turbidity meter in stock here from our factory. We also accept customized orders.

 

 
 
product key technologies
ZD2

The ZD‑Series Intelligent Handheld Turbidity Meter is built upon a professional optical design and relies on the classic scattered light principle for measurement. To ensure global consistency and traceability of results, calibration is performed with Formazin standard solution-an internationally accepted reference-so the data meets worldwide testing specifications.

A notable feature of this handheld turbidity meter is its excellent linearity across the full measurement range. For any sample type, from low‑turbidity purified water to high‑turbidity sewage, the optical response stays stable. Readings are accurate, repeatable, and dependable. Compared with ordinary turbidity meters, the ZD series improves its internal algorithm and optical layout, which reduces measurement errors and enhances overall stability.

Portability is another key strength. Lightweight and compact, the unit is ideal for field inspections, outdoor sampling, emergency on‑site checks, or routine patrols. You are not tied to a fixed laboratory-carry it to rivers, reservoirs, factory floors, or municipal water plants, and test right there, on the spot.

Operating the device is straightforward. The user‑friendly design keeps steps simple, and the display is clear. On‑site personnel do not need deep technical knowledge: calibration, sample testing, and data reading can all be completed in just a few steps. Inside, an intelligent processing module automatically handles signal conditioning and reading stabilization, removing the risk of manual errors and making testing faster and more convenient.

This handheld turbidity meter sees wide use in environmental monitoring, waterworks, pharmaceuticals, beverages, brewing, and industrial water quality checks. It delivers accurate turbidity readings that support production quality control, water resource protection, and standardized wastewater management-a practical, high‑performance tool across many industries.

The portable turbidity meter mainly consists of an optical detection system, a sample cell and flow path structure, a signal processing & display unit, a power supply, and an outer casing. This structural design ensures accurate, stable measurements and convenient field operation.

The signal processing and display unit converts optical signals into readable data and enables human‑machine interaction. A built‑in microprocessor and algorithmic chip transform the signals captured by detectors into turbidity readings. Certain models also support a rapid‑sedimentation measurement mode, using dedicated algorithms to handle quickly settling samples.

Equipped with a high‑brightness LCD, TFT color screen, or color touch panel, the operation display includes backlight adjustment and multi‑language menus, making it easy to read and operate even under strong outdoor sunlight.

ZD4

 

Technical Parameter

 

Model

ZD-2A

ZD-10A

Principle

90° scattered light

Minimum Indication

0.1 NTU

Measuring Range

0~200 NTU

0~1000 NTU

Calibration

0 NTU, 100 NTU

0 NTU, 50 NTU, 100 NTU, 200 NTU, 400 NTU, 800 NTU, 1000 NTU

Indication Error

±8% (±2.5% FS)

Repeatability

≤0.8%

Zero Drift

±0.8% FS

Weight

0.5KG

Size

210×75×70mm

Power Supply

DC 1.5V × 5 AA alkaline dry batteries, AC 220V/50Hz/DC 7.5V/0.2A power adapter, automatic shutdown, AC/DC dual function

Feature

Popular type, wide measurement range, suitable for water plants, good stability

 

Model

ZD-201

ZD-401

ZD-501

ZD-801

ZD-1001

Principle

90° scattered light

Measurement Range (NTU)

0-100/0.01

100-200/0.1

0-100/0.01

100-400/0.1

0-100/0.01

100-500/0.1

0-100/0.01

100-800/0.1

0-100/0.01

100-1000/0.1

Minimum Display Value (NTU)

0.1/0.01

Calibration Point

2 points

5 points

6 points

6 points

7 points

Display Error

±6% (±2% FS)

Repeatability

≤0.5%

Zero Drift

±0.5% FS

Weight

1.5KG

Size

370×260×160mm

Power Supply

AC 220V/50HZ

Feature

Equipped with a microcomputer, the instrument has an average measurement mode, data storage and query function, automatic range switching, etc.

FAQ

Q: Why cannot the calibration be performed?

A: Possible causes: Expired calibration solution, incorrect concentration of calibration solution, contaminated sensor, etc.
Solutions: Replace the calibration solution and ensure it is within the valid period; verify the concentration of the calibration solution; clean the sensor, and replace it if necessary.

Q: Why is there a large discrepancy between measured values and actual values?

A: Possible causes: Incorrect calibration, damaged sensors, excessively high or low water sample temperature, etc.
Solutions: Perform recalibration with standard solutions; check if the sensor needs replacement; keep the water sample temperature within the appropriate range.

 

FAQ

Q: Why cannot the calibration be performed?

A: Possible causes: Expired calibration solution, incorrect concentration of calibration solution, contaminated sensor, etc.
Solutions: Replace the calibration solution and ensure it is within the valid period; verify the concentration of the calibration solution; clean the sensor, and replace it if necessary.

Q: Why is there a large discrepancy between measured values and actual values?

A: Possible causes: Incorrect calibration, damaged sensors, excessively high or low water sample temperature, etc.
Solutions: Perform recalibration with standard solutions; check if the sensor needs replacement; keep the water sample temperature within the appropriate range.

Q: What causes the readings to be abnormally high or low?

A: Possible causes: Inaccurate calibration, contaminated sensors, aging equipment and so on.
Solutions: Perform recalibration using standard solutions; clean the sensor and replace it if needed; check whether the instrument requires maintenance or replacement.

 

 

Hot Tags: handheld turbidity meter, China handheld turbidity meter manufacturers, suppliers, factory