Laboratory Portable Turbidity Meter

Laboratory Portable Turbidity Meter
Details:
Model: ZD-201, ZD-401, ZD-501, ZD-801, ZD-1001
Principle: 90° scattered light
Minimum Display Value: 0.1/0.01 NTU
Display Error: ±6% (±2% FS)
Send Inquiry
Description
Send Inquiry

Hangzhou Qiwei Instrument Co., Ltd. is one of the leading manufacturers and suppliers of laboratory portable turbidity meter in China. With a professional production team, we are able to meet the needs of the majority of our customers. Welcome to wholesale bulk laboratory portable turbidity meter in stock here from our factory. We also accept customized orders.

 

 
 

 

For organizations that require numerical turbidity analysis in a small instrument format, the ZD series laboratory lightweight turbidity meter is designed.

The device supports turbidity measurement across a range of values, from low-turbidity samples to higher-turbidity water, using the 90° scattered-light measurement principle. Five models are included in the sequence: ZD-201, ZD-401, ZD-501, ZD-801, and ZD-1001. The device supports routine water testing and measurement record review with a specified repeatability of 0.5%, zero drift of 0.5%, average measurement mode, and data storage and query functions.

Users should consider the assessment range, available power source, environmental protection, and supplement construction before choosing a model for mobile lab programs, emergency water testing, and field research projects. This helps to ensure that the device is operating in accordance with the testing setting.

 

product key technologies
01

The intelligent turbidimeter adopts the scattered light principle and uses Formazin standard solution, which is internationally recognized, for calibration. As a precise and intelligent instrument, it features good linearity in turbidity measurement, accurate and reliable readings, and easy operation.

This instrument is suitable for waterworks, reclaimed water treatment plants, swimming pool water reuse, food and beverage industries, etc. It is an essential instrument for water laboratories.

Application

 

The ZD collection laboratory compact turbidity sensor can be considered for testing programs that require turbidity measurement at momentary or cellular testing locations. Its software suitability depends on the selected design, available power source and site operating conditions.

Mobile Laboratory and Water Quality Testing Vehicles

Mobile facilities are often used to conduct preliminary water value assessments near picking locations. A portable-format viscosity meter can help test measurement inside a properly prepared testing vehicle, reducing the need to transfer every sample to a fixed laboratory before obtaining an original turbidity result.

Emergency Water Quality Assessment

During overflow response, water supply incidents or another emergency inspection activities, testing teams may need to evaluate turbidity at momentary random points. The ZD set can be evaluated as part of an incident liquid testing setup where a suitable power supply, sample planning area and operating conditions are applicable.

Disease Control and Public Health Laboratories

Disease command centers and public health laboratories may involve viscosity measurement in waters quality inspection programs. The instrument does assistance routine analysis of collected water samples and offer measurement records for later review. Its eligibility for a particular public health testing procedure may be assessed against the laboratory's appropriate methods and requirements.

Field Research and Environmental Investigation

Water samples can be collected from lakes, reservoirs, dams, and other outdoor locations by climate research teams. When the necessary power and sample handling conditions are present, the instrument can be used in a momentary testing facility or a portable laboratory.

Before deploying in exposed outside environments, users should verify the instrument's environmental protection rating and power configuration for portable and emergency applications.

 

Technical Parameter

Model

ZD-201

ZD-401

ZD-501

ZD-801

ZD-1001

Principle

90° scattered light

Measurement Range (NTU)

0-100/0.01
100-200/0.1

0-100/0.01
100-400/0.1

0-100/0.01
100-500/0.1

0-100/0.01
100-800/0.1

0-100/0.01
100-1000/0.1

Minimum Display Value

0.1/0.01 NTU

Calibration Point

2 points

5 points

6 points

6 points

7 points

Display Error

±6% (±2% FS)

Repeatability

≤0.5%

Zero Drift

±0.5% FS

Weight

1.5 kg

Size

370×260×160 mm

Power Supply

AC 220V/50Hz

Feature

Equipped with a microcomputer, the instrument has an average measurement mode,

data storage and query function, automatic range switching, etc.

Environmental Protection and Power Supply Options

 

Before deployment, the instrument's power configuration and operating environment should be considered for portable water testing.

Environmental protection

When using the device in environments where dirt, splashes, or water may be present, please refer to the proved product protection rating. The technical documents from the manufacturer should be used to determine the actual protection level and permitted operating conditions.

Power Supply for Testing on Mobile Devices

Energy supply is a crucial component of device configuration for mobile labs and emergency testing projects. Before placing an order, please verify the supported power input and any recommended external power sources. When requesting a quote, please describe whether battery operation or vehicle power modification is required.

Application Note: The product manual specifies the ecological and electrical conditions under which the instrument should operate. If the approved protection rating for use is not in place, don't use it in rain, washdown, or damp outdoor conditions.

 

FAQ

 

1. What models are available in the ZD series laboratory portable turbidity meter?

Five models are included in the set: ZD-201, ZD-401, ZD-501, ZD-801, and ZD-1001. Users can choose a design based on the expected turbidity levels of their samples because of their different measurement ranges.

 

2. What is the repeatability of the ZD series turbidity meter?

The published repeatability rate is 0.5%. For evaluating measurement consistency under equivalent testing conditions, this specification serves as a reference.

 

3. Can the instrument be used in a mobile laboratory or water testing vehicle?

When there is enough energy to power the device, where are the samples prepared, and where are the working conditions, the device might be suited for mobile lab setups. Before placing an order, please verify the power configuration and transport requirements.

 

4. Does the laboratory portable turbidity meter support outdoor operation?

The recommended awareness of environmental protection, power source, and operating problems affect outdoor use. Before using the device in uncovered locations, please consult the manufacturer for the relevant IP rating and environmental requirements.

 

Hot Tags: laboratory portable turbidity meter, China laboratory portable turbidity meter manufacturers, suppliers, factory, Beer Turbidity Meter, Benchtop Digital Turbidity Meter, Benchtop McFarland Turbidity Meter, Laboratory Benchtop Turbidity Meter, Portable Bacterial Turbidity Meter, Portable Turbidity Meter

Send Inquiry
Send Inquiry